Maple für Professional
Maple für Akademiker
Maple für Studenten
Maple Personal Edition
Maple Player
Maple Player für iPad
MapleSim für Professional
MapleSim für Akademiker
Maple T.A. - Testen & beurteilen
Maple T.A. MAA Placement Test Suite
Möbius - Online-Courseware
Machine Design / Industrial Automation
Luft- und Raumfahrt
Fahrzeugtechnik
Robotics
Energiebranche
System Simulation and Analysis
Model development for HIL
Anlagenmodelle für den Regelungsentwurf
Robotics/Motion Control/Mechatronics
Other Application Areas
Mathematikausbildung
Technik
Allgemein- und berufsbildende Schulen
Testen und beurteilen
Studierende
Finanzmodelle
Betriebsforschung
Hochleistungsrechnen
Physik
Live-Webinare
Aufgezeichnete Webinare
Geplante Veranstaltungen
MaplePrimes
Maplesoft-Blog
Maplesoft-Mitgliedschaft
Maple Ambassador Program
MapleCloud
Technische Whitepapers
E-Mail Newsletters
Maple-Bücher
Math Matters
Anwendungs-Center
MapleSim Modell-Galerie
Anwenderberichte
Exploring Engineering Fundamentals
Lehrkonzepte mit Maple
Maplesoft Welcome-Center
Resource-Center für Lehrer
Help-Center für Studierende
Quality Control of a Paint Production Process
Introduction
1. Formulation of Reaction Kinetics Equation
2. Derivation of the Reaction Kinetics Model
3. Validation of the Reaction Kinetics Model
4. Updated Reaction Kinetics Model
Quality control in terms of paint production consists of sampling at regular intervals to ensure that the end product meets a set of target criteria, which include desired yield and concentration levels. These criteria are determined by developing a model to accurately represent the reaction kinetics of the system. With a highly accurate model of the chemical process one can quickly identify and correct sources of error during the production process.
During a routine sample control inspection, a quality control engineer identified a significant discrepancy between the expected and actual concentration of paint produced in the reactor; the concentration of paint produced was double the expected value. This application illustrates how Maple was used to identify and subsequently correct the source of error between the model-predicted and actual concentrations of paint produced.
1. Formulation of the Reaction Kinetics Equation
The equations that define the chemical process are shown below. The reactants, A and B, are mixed together while carbon dioxide is continuously added to produce a desired third compound C. In the interest of commercial competition, the names of the chemical species have been changed.
We can define the above reaction scheme as a mathematical system, using the equation below:
,
with and
The matrix, M, is of rank 5 and given by:
and the function f by:
where the and are auxiliary variables given by:
The variables , , , , , and , are the concentrations of the following compounds , , , , and , respectively. The partial pressure of is given by and H is Henry's law constant.
Using the information above, we can derive the system of nonlinear differential-algebraic equations (DAEs) that models the chemical process described above.
Rearranging the equations derived above, we end up with a stiff system of 6 non-linear DAEs of index 1. Although there is no single formulation, stiffness is usually defined as an equation (or system of equations) with terms that can lead to rapid variations in the solution.
=
We now create a system model containing the equations derived above and the initial conditions.
The values of the physical parameters and initial conditions of the system are given by:
Parameters
Initial Conditions
We can now solve the DAE system and plot how the concentrations of the various compounds change with time using the command
3. Validation of Reaction Kinetics Model
The discrepancy between the actual and expected concentration of compound C was revealed by comparing the experimental reaction kinetics for each compound to the predicted values.
The experimental data, stored in an Excel file, was extracted using the following commands:
The following commands extract the values from Excel:
The following plots show the experimental versus predicted reaction kinetics for each compound. From these results, it is apparent that the model derived in the previous section does not adequately predict the experimental results for compound A and compound C.
In fact, the concentration of compound C at steady state is , which is 1.5 times lower than the steady state concentration observed via the experimental data. Similarly, the concentration of compound A at steady state is , which is 1.3 times smaller than the steady state concentration obtained via the experimental data.
The statistical calculations (mean, standard deviation, and root-mean square error), confirm the presence of an error in one of the rate constants controlling the concentration of compound A. The data, summarized below, show the root mean square error of compound A to be 0.00301799 which is several orders larger than the root mean square error values of the other compounds.
Predicted and Experimental Mean of the Reaction Kinetics for each Compound
Predicted Mean
Experimental Mean
Difference
Predicted and Experimental Standard Deviation of the Reaction Kinetics for each Compound
Predicted Std
Experimental Std
Root-Mean Square Error
A better prediction for the reaction kinetics of compound A can be obtained by parameterizing the numerical solution for the differential equation obtained earlier, and fitting the theoretical model to the experimental data using the least-squares approach.
The following procedure calculates the sum of the squares of the error between the experimental data and the model prediction for the rate constant . It assumes that the only uncertainty in the experimental data exists in the concentration, . In reality, the time the reading was taken will also be subject to a degree of error. If this was to be taken into account, then the following procedure can be easily modified to calculate the sum of the short orthogonal distance between the data points and model predictions; this is also known as orthogonal regression.
The value of that best describes the experimental data is
This value for is much smaller than the value of that was used to develop the original model (that is, 10.925 vs. 28.7).
Taking into account the new value of as shown below, the theoretical model accurately predicts the experimental results.
With this new rate constant, the concentration of compound C now more accurately matches the concentration being produced at the plant.