Single Stub Matching - Maple Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.
Our website is currently undergoing maintenance, which may result in occasional errors while browsing. We apologize for any inconvenience this may cause and are working swiftly to restore full functionality. Thank you for your patience.

Online Help

All Products    Maple    MapleSim


Single Stub Matching of a Transmission Line

Introduction

A single short circuited transmission line is a distance d from the load and of length d.

Given a characteristic impedance of Z0 and a load with complex impedance ZL, this application will calculate the values of d and l.

 

• 

The real part of the impedance at the stub location must match the transmission line characteristic impedance

• 

The imaginary part of the impedance at the stub location must equal 0

 

Reference:

Iskander, Magdi F., Electromagnetic Fields and Waves, Prentice-Hall, Inc., Englewood Cliffs, NJ, 1992.

 

restart:assumed,real,l,real

Parameters

Resistances

Z__050 ohms:

Z__L35 47.5 Iohms:

Equations

Wavelength and propagation constant

λ1m:

β2π/λ:

circuitZ__0cosβd+IZ__LsinβdZ__Lcosβd+IZ__0sinβdIcotβl:

Stub Location

The location and length of the stub are

fsolveRecircuit=1, Imcircuit=0,l=0.1 m,d=0.1 m

d~=58.94×10-3m,l~=111.18×10-3m

(4.1)