Polyphase Triac
Simplified polyphase triac
Description
Connections
Parameters
Modelica Standard Library
The Polyphase Triac component consists of m Single Phase Triac components. The parameter m is the number of output phases.
Thyristor1 has to be fired during the positive halfwave, thyristor2 has to be fired during the negative halfwave.
Name
Modelica ID
Vectorized boolean input; firing signals for thyristor1
fire1
Vectorized boolean input; firing signals for thyristor2
fire2
Vector of positive connections
plug_p
Vector of negative connections
plug_n
Conditional vector of heat ports
heatPort
Default
Units
Number of phases
m
Forward state-on differential resistance
Ron
Backward state-off conductance
Goff
Forward threshold voltage
Vknee
Use Heat Port
True (checked) means heat port is enabled
useHeatPort
Fixed temperature, if use heat port is false
T
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.