Delta-Wye Transformers
Dy01 Dy03 Dy05 Dy07 Dy09 Dy11
Three-phase transformers with delta primary and wye secondary windings
Description
Connections
Parameters
Modelica Standard Library
The Delta-Wye (or Dy) components are three-phase transformers with delta primary and wye secondary windings.
The base name of each component is Dyij, where ij are two digits that specify the phase shift between the primary and secondary windings. The numbers range from 0 to 12 and correspond to the hours on the face of a clock. For example, 01 corresponds to a phase shift of 30 degrees.
Name
Modelica ID
Primary plug
plug1
Secondary plug
plug2
Secondary star-point connection
starpoint2
Optional thermal port
thermalPort
General Parameters
Default
Units
Ratio primary voltage (line-to-line) / secondary voltage (line-to-line)
n
Operational temperature of primary resistance
T1Operational
Operational temperature of secondary resistance
T2Operational
Use Thermal Port
True (checked) means thermal port is enabled
useThermalPort
Nominal Resistances And Inductances Parameters
Primary resistance per phase at TRef
R1
Reference temperature of primary resistance
T1Ref
Temperature coefficient of at
alpha20_1
Primary stray inductance per phase
L1sigma
Secondary resistance per phase at TRef
R2
Reference temperature of secondary resistance
T2Ref
alpha20_2
Secondary stray inductance per phase
L2sigma
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
Electrical Library
Electrical Machines
Electrical Machines Transformers