Single Stub Matching of a Transmission Line

Introduction

A single short circuited transmission line is a distance d from the load and of length d.

Given a characteristic impedance of Z0 and a load with complex impedance ZL, this application will calculate the values of d and l.

 

• 

The real part of the impedance at the stub location must match the transmission line characteristic impedance

• 

The imaginary part of the impedance at the stub location must equal 0

 

Reference:

Iskander, Magdi F., Electromagnetic Fields and Waves, Prentice-Hall, Inc., Englewood Cliffs, NJ, 1992.

 

> 

restart:assumed,real,l,real

Parameters

Resistances

> 

Z__0≔50 ohms:

> 

Z__L≔35− 47.5 Iohms:

Equations

Wavelength and propagation constant

> 

λ≔1m:

> 

β≔2⋅π/λ:

> 

circuit≔Z__0⋅cosβ⋅d+I⋅Z__L⋅sinβ⋅dZ__L⋅cosβ⋅d+I⋅Z__0⋅sinβ⋅d−I⋅cotβ⋅l:

Stub Location

The location and length of the stub are

> 

fsolveRecircuit=1, Imcircuit=0,l=0.1 m,d=0.1 m

d~=58.94×10-3⁢m,l~=111.18×10-3⁢m

(4.1)