Delta-Delta - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

Quasistatic Delta-Delta Transformers

Dd00  Dd02  Dd04  Dd06  Dd08  Dd10

Three-phase transformers with delta primary and delta secondary windings

 

Description

Connections

Parameters

Modelica Standard Library

Description

The Quasistatic Delta-Delta Transformers are three-phase transformers with delta primary and delta secondary windings.

The base name of each component is Ddij, where ij are two digits that specify the phase shift between the primary and secondary windings. The numbers range from 0 to 12 and correspond to the hours on the face of a clock. For example, 02 corresponds to a phase shift of 60 degrees.

Connections

Name

Description

Modelica ID

Primary plug

plug1

Secondary plug

plug2

Optional thermal port

thermalPort

Parameters

General Parameters

Name

Default

Units

Description

Modelica ID

Ratio primary voltage (line-to-line) / secondary voltage (line-to-line)

n

Operational temperature of primary resistance

T1Operational

Operational temperature of secondary resistance

T2Operational

Use Thermal Port

 

True (checked) means thermal port is enabled

useThermalPort

Nominal Resistances And Inductances Parameters

Name

Default

Units

Description

Modelica ID

 

Primary resistance per phase at TRef

R1

Reference temperature of primary resistance

T1Ref

Temperature coefficient of  at

alpha20_1

 

Primary stray inductance per phase

L1sigma

 

Secondary resistance per phase at TRef

R2

Reference temperature of secondary resistance

T2Ref

Temperature coefficient of  at

alpha20_2

 

Secondary stray inductance per phase

L2sigma

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.