DQ To Three Phase
Transforms dq to three-phase
Description
Connections
Parameters
Modelica Standard Library
The DQ To Three Phase component transforms dq currents or voltages to three-phase currents or voltages. The desired d- and q-components of the space phasor in rotor fixed coordinate system are given by inputs and . Using the given rotor position (input ), the correct three-phase values (output ) are calculated. They can be used to feed a current source which in turn feeds an induction machine. Inputs and can be given either as peak values () or as RMS (). The correction by factor is done automatically.
Name
Modelica ID
Connector of Real output signals
y
d-component
d
q-component
q
Rotor angle
phi
General Parameters
Default
Units
Number of phases
m
Number of pole pairs
p
Uses RMS
If true, inputs dq are multiplied by sqrt(2)
useRMS
Constant Parameters
Number of outputs
nout
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
Electrical Library
Electrical Machines
Electrical Machines Utilities
Download Help Document