The DCV 32 Open component is a three-port, two-position valve. Typically, port 1 is connected to the pressure line, port 2 is the outlet port, and port 3 is the exhaust port.
There are two paths between different ports in this valve, port 1 to port 2 (1-2), and port 2 to port 3 (2-3). Note that is the minimum sonic conductance for all the paths while there is a specific maximum sonic conductance, , for each path. There is also a specific critical pressure ratio, , for each path.
The sonic conductance for the path between pairs of ports varies as a function of the spool input signal, , for that path, , and . The following table gives the sonic conductance values for the two end values of the spool signal.
Spool Input
|
1-2
|
2-3
|
0
|
|
|
1
|
|
|
|
|
Transitions are centered at the midpoint, with the width given by the parameter, as shown in the following diagram.